Signal samples from the CSA production can be found in DAS, by typing in the query window:
To implement the cut-based electron identification we produced private MINIAODSIM samples with few events (100K), using the common ID and Isolation Toolkit CITK.
To access the private samples from lxplus, you have to obtain a valid grid proxy (voms-proxy-init --voms cms
). The process.source
in your configure file should look like the following:
process.source = cms.Source("PoolSource", fileNames = cms.untracked.vstring('root://cmsxrootd.fnal.gov//store/user/jruizvar/RSGravToZZ/M1000/RSGravToZZ_kMpl01_M-1000_Tune4C_13TeV-pythia8_MINIAODSIM_PU20bx25_1.root') )
MINIAODSIM samples contain information about generated and reconstructed particles. Our matching algorithm identifies the closest genElectron for every recoElectron, as well as the particle ID of the genElectron's ancestor.
The deltaR and PID matching allows to define four categories as described in the following table:
1 | Unmatched |
deltaR(closest gen electron, reco electron) > 0.2 |
---|---|---|
2 | Prompt electron |
deltaR(closest gen electron, reco electron) < 0.2 (without ancestor) |
3 | True electron from tau |
deltaR(closest gen electron, reco electron) < 0.2 AND (ancestor PID == 15) |
4 | True electron from Z |
deltaR(closest gen electron, reco electron) < 0.2 AND (ancestor PID == 23) |
5 | Anything else |
What remains from above |
The efficiency is the number of signal electrons passing the ID divided by the total. The fake rate was estimated in a similar way but using the non-signal electrons.
To access the electronID, which is a member function of the
pat::Electron
class, we used a line like the following:
int passID = ( el->electronID("cutBasedElectronID-CSA14-PU20bx25-V0-standalone-veto") > 0.5 );
The cut-based electron identification recommended by EGM for Run 2 analyses, determines four working points: veto, loose, medium, and tight. A detailed description here.
Particle flow isolation with delta beta correction is calculated as follows:
reco::GsfElectron::PflowIsolationVariables pfIso = el->pfIsolationVariables(); absiso = pfIso.sumChargedHadronPt + std::max(0.0 , pfIso.sumNeutralHadronEt + pfIso.sumPhotonEt - 0.5 * pfIso.sumPUPt ); relIsoWithDBeta = absiso/pt;
Internally, the isolation variables use the standard recommended cone size deltaR = 0.3
. Details here.
* Electron isolation after different cut-based selections
To estimate the efficiency and fake rate of the electron identification, we classified the electrons according to its matching category and the passID associated to the cutBasedElectronID-CSA14 working points.
The classification for each working point is displayed as a TH2 histogram with two bins in the Y axis associated to the passID variable, and four bins in the X axis corresponding to the matching categories. The number of entries inside each box of the histogram indicates the number of electrons in a given matching category with a given passID.
Efficiency and fake rate as function of genElectron's pT and eta are shown below:
The analyzer developed for these studies is attached below:
I | Attachment | History | Action | Size | Date | Who | Comment |
---|---|---|---|---|---|---|---|
![]() |
BuildFile.xml.txt | r1 | manage | 0.3 K | 2014-09-29 - 09:29 | JoseRuiz | BuildFile for ElectronID studies |
![]() |
EDBRGenStudies.cc.txt | r2 r1 | manage | 9.1 K | 2014-09-29 - 15:55 | JoseRuiz | Analyzer for ElectronID studies |
![]() |
MCTruth_RSGravToZZ_M1000.py.txt | r1 | manage | 2.7 K | 2014-09-29 - 09:32 | JoseRuiz | Configure file for ElectronID studies and sample RSGravToZZ-M1000 |
![]() |
MCTruth_RSGravToZZ_M4500.py.txt | r1 | manage | 2.8 K | 2014-09-29 - 09:21 | JoseRuiz | Configure file for ElectronID studies |
![]() |
RSGravToZZ-M1000_matchId.png | r2 r1 | manage | 35.3 K | 2014-09-29 - 08:49 | JoseRuiz | Classification of electrons in sample RSGravToZZ-M1000 |
![]() |
RSGravToZZ-M4500_matchId.png | r2 r1 | manage | 35.2 K | 2014-09-29 - 08:50 | JoseRuiz | Classification of electrons in sample RSGravToZZ-M4500 |
![]() |
deltaR.png | r2 r1 | manage | 21.2 K | 2014-09-29 - 11:32 | JoseRuiz | DeltaR matching |
![]() |
eff_dR.png | r2 r1 | manage | 41.4 K | 2014-09-29 - 16:00 | JoseRuiz | Efficiency as function of deltaR(genElectron1, genElectron2) |
![]() |
eff_dR_zoom.png | r1 | manage | 39.0 K | 2014-09-30 - 13:33 | JoseRuiz | Efficiency as function of deltaR(genElectron1, genElectron2) zoom in the low deltaR region |
![]() |
eff_eta.png | r3 r2 r1 | manage | 73.9 K | 2014-09-29 - 08:57 | JoseRuiz | Efficiency and fake rate as function of genElectron's eta |
![]() |
eff_pt.png | r4 r3 r2 r1 | manage | 72.2 K | 2014-09-29 - 11:43 | JoseRuiz | Efficiency and fake rate as function of genElectron's pT |
![]() |
formulas.png | r2 r1 | manage | 70.2 K | 2014-09-29 - 08:42 | JoseRuiz | Efficiency and fake rate formulas |
![]() |
iso.png | r4 r3 r2 r1 | manage | 47.3 K | 2014-09-29 - 09:35 | JoseRuiz | Electron isolation with delta beta correction |